Required documents found
Required items correctly found or flagged, checked against your assessor’s labelled files.
For notified and certification bodies
A technical file completeness check confirms, before content review, that every document the scheme requires is present, current and easy to find. EvalLens checks the technical file against your checklist and shows what is missing or hard to find; assessors confirm readiness for detailed review.
Custom workflow · Starts with an agreed pilot
Illustrative sample: a medical device’s technical file, the applicable checklist and document versions.
A request for missing documents goes to the applicant only after your assessor approves it.
A complete technical file is not a conformity decision. Your assessors judge whether the evidence is adequate and raise any nonconformity; tests, site visits and other required checks stay part of the assessment.
One medical device’s technical file against five checklist items, from the illustrative materials: where each document is and its status.
Sample output · Illustrative materials · Not a client document · Technical file · Completeness record
| Item | Document in the file | Status |
|---|---|---|
| Device description and specification | Technical file, section 1 | Located |
| Risk management file (ISO 14971) | Risk management report, version 3 | Located |
| Test report IEC 60601-1 The example above | Missing Confirmed by your assessor | |
| Clinical evaluation report | Clinical evaluation report, no version date | Version to check |
| Labelling and instructions for use | Instructions for use, draft 2 | Located |
Device description and specification
Risk management file (ISO 14971)
Test report IEC 60601-1
The example above
Clinical evaluation report
Labelling and instructions for use
A confidential engagement: source-linked document checks for an audit team, each finding brought together with the application and its supporting evidence for the auditor to verify. The organisation and outcomes are not disclosed.
Choose closed files from one scheme and a checklist version. We configure a completeness check and compare it with your assessors’ reviewed records. Before launch we agree what needs an assessor’s approval.
Required items correctly found or flagged, checked against your assessor’s labelled files.
False missing-document flags, and the clarification requests they would have triggered, counted on the same closed files.
Time to locate and verify evidence within one scheme, requirement version and review stage.
Pilots start at $25,000 USD; the final price depends on the scope of the pilot.
Start with file completeness for one scheme. Requirement mapping and audit responses can follow as separate tasks.
During technical assessment
AI locates documents and passages for the requirements your assessors select.
Assessors decide whether the requirement applies and the evidence is sufficient.
After a nonconformity
AI brings each nonconformity, the organisation’s response and its supporting records together for review.
Authorised reviewers decide whether the nonconformity can be closed.
Under the EU Medical Device Regulation, a notified body starts by checking that the application is complete, and the certification decision follows a final review by people who did not take part in the assessment. EvalLens works on the preparation steps. The table uses the MDR as described by Team-NB, the association of notified bodies; other schemes name the steps differently.
| Step | What happens | Where EvalLens helps | Who decides |
|---|---|---|---|
| Application review | The notified body checks “the completeness of those applications” against the conformity assessment procedure (MDR Annex VII §4.3) | A checklist with each document’s location and the missing items | Notified body staff |
| Technical documentation assessment | Evidence is assessed against each requirement | An evidence table by requirement, with file and passage | Assessor |
| Tests, audits and site visits | Checks the scheme requires | Not in scope | Assessor |
| Nonconformities | The organisation’s response and supporting records are reviewed | Each nonconformity matched to its response and records | Authorised reviewer |
| Final review and decision | Carried out by “personnel who have not been involved in the conformity assessment procedure” | Not in scope | Certification decision maker |
A check for missing documents before content review exists in most regulated reviews. Here is how three of them describe it.
| Regime | The completeness step | Note |
|---|---|---|
| EU MDR and IVDR | Application review starts with a completeness check (Annex VII §4.3, as quoted by Team-NB) | Commission survey: 14 of 52 MDR and 5 of 19 IVDR notified bodies say most submissions arrive complete |
| US FDA, 510(k) | The Refuse to Accept policy (2022) decides whether a submission is accepted for substantive review | FDA’s MDUFA V assessment says the eSTAR template automates submission verification, removing a separate Refuse to Accept review for certain submissions |
| Accredited certification (IAF members) | IAF MD 4:2025, applicable from 30 January 2026, sets rules for using information and communication technology in conformity assessment | Its definition of ICT names “artificial intelligence”; its examples include reviewing documents and records by remote access |